MultiPlus-II — Slim, Single AC Input Inverter/Charger
1284 available | Ships in 1-2 days
☑️ One AC Input & Two AC Outputs
☑️ Single High-Capacity ATS
☑️ Modular Configuration for Single, Split or 3-Phase
💡 Have a Question? Get a Real Answer >
Downloads
Enclosure dimensions
- MultiPlus-II 24V 48V 3000VA 230V PMP242305010 PMP482305010
- MultiPlus-II 24V 48V 3000VA 230V PMP242305010 PMP482305010 (3D)
- MultiPlus-II 24V 48V 3000VA 230V PMP242305010 PMP482305010 (stp)
- MultiPlus-II 48/5000/70-50 230V PMP482505000 (3D)
- MultiPlus-II 48/5000/70-50 230V PMP482505000 (stp)
- MultiPlus-II 48/5000/70-50 230V PMP482505000
- MultiPlus-II 48/8000/110-100 230V
- MultiPlus-II 48/8000/110-100 230V (3D)
- MultiPlus-II 48/8000/110-100 230V (stp)
- MultiPlus-II 48/10000/140-100 230V
- MultiPlus-II 48/10000/140-100 230V (3D)
- MultiPlus-II 48/10000/140-100 230V (stp)
- MultiPlus-II 12/3000/120-32 230V
- MultiPlus-II 12/3000/120-32 230V (3D)
- MultiPlus-II 12/3000/120-32 230V (stp)
- MultiPlus-II 48/15000/200-100 230V
- MultiPlus-II 48/15000/200-100 230V (3D)
- MultiPlus-II 48/15000/200-100 230V (stp)
- MultiPlus-II 24/5000/120-50 230V
- MultiPlus-II 24/5000/120-50 230V (3D)
- MultiPlus-II 24/5000/120-50 230V (stp)
- MultiPlus-II 12/3000/120-50 120V (UL)
- MultiPlus-II 12/3000/120-50 120V (UL) (3D)
- MultiPlus-II 12/3000/120-50 120V (UL) (stp)
- MultiPlus-II 24/3000/70-50 120V (UL)
- MultiPlus-II 24/3000/70-50 120V (UL) (3D)
- MultiPlus-II 24/3000/70-50 120V (UL) (stp)
- MultiPlus-II 48/3000/35-50 120V (UL)
- MultiPlus-II 48/3000/35-50 120V (UL) (3D)
- MultiPlus-II 48/3000/35-50 120V (UL) (stp)
- MultiPlus-II 48/5000/70-50 230V PMP482505012 (HQ2241 onwards)
- MultiPlus-II 48/5000/70-50 230V PMP482505012 (3D) (HQ2241 onwards)
- MultiPlus-II 48/5000/70-50 230V PMP482505012 (stp) (HQ2241 onwards)
- MultiPlus-II 48/5000/70-50 230V PMP482505010 (Till and included HQ23xx)
- MultiPlus-II 48/5000/70-50 230V PMP482505010 (3D) (Till and included HQ23xx)
- MultiPlus-II 48/5000/70-50 230V PMP482505010 (stp) (Till and included HQ23xx)
- MultiPlus-II 48/3000/35-32 230V PMP482305012
- MultiPlus-II 48/3000/35-32 230V PMP482305012 (3D)
- MultiPlus-II 48/3000/35-32 230V PMP482305012 (stp)
- MultiPlus-II 48/5000/70-95 120V
- MultiPlus-II 48/5000/70-95 120V (3D)
- MultiPlus-II 48/5000/70-95 120V (stp)
- MultiPlus-II 48/5000/70-50 230V PMP482505010 (From HQ2345 onwards)
- MultiPlus-II 48/5000/70-50 230V PMP482505010 (3D) (From HQ2345 onwards)
- MultiPlus-II 48/5000/70-50 230V PMP482505010 (stp) (From HQ2345 onwards)
- MultiPlus-II 24/5000/120-95 120V
- MultiPlus-II 24/5000/120-95 120V (3D)
- MultiPlus-II 24/5000/120-95 120V (stp)
- MultiPlus-II 12/5000/220-50 230V
- MultiPlus-II 12/5000/220-50 230V (3D)
- MultiPlus-II 12/5000/220-50 230V (stp)
Manuals
- Connecting other lithium battery systems to Multis and Quattros
- ESS (Energy Storage System) - Start page
- VE.Bus parallel split- and three-phase systems
- VE.Bus Error Codes
- Configuring solar systems with Quattros and Multis
- AC-coupling and the Factor 1.0 rule
- Automatic Generator start-stop (PDF)
- Automatic Generator start-stop (HTML5)
- MultiPlus-II AU-Off grid (PDF)
- MultiPlus-II GX (HTML5)
- MultiPlus-II GX (PDF)
- MultiPlus-II 230V AU ESS (PDF)
- VictronConnect configuration guide for VE.Bus products (HTML5)
- VictronConnect configuration guide for VE.Bus products (PDF)
- Solar & Wind Priority (HTML5)
- Solar & Wind Priority (PDF)
- Energy Storage System (HTML5)
- Energy Storage System (PDF)
- Pre-RMA Bench Test Instructions (HTML5)
- Pre-RMA bench test instructions (PDF)
- MultiPlus-II 230V (HTML5)
- MultiPlus-II 230V (PDF)
- MultiPlus-II 120V (HTML5)
- MultiPlus-II 120V (PDF)
- MultiPlus-II External Transfer Switch application (HTML5)
- MultiPlus-II External Transfer Switch application (PDF)
System schematics
- SLD - MPPT MultiPlus-II - off-grid
- SLD - Parallel MultiPlus-II with gen - off-grid
- SLD - MultiPlus-II AC PV and grid - backup
- SLD - MultiPlus-II AC PV and gen - off-grid
- MultiPlus-II 3kW 120VAC 12VDC 400Ah Li VEBus BMS generator MPPT BMV CCGX Orion-Tr Smarts Lynx distributor
- MultiPlus-II 3kW 120VAC 12VDC 400Ah Li VEBus BMS generator MPPT BMV Cerbo Orion-Tr Smarts
- MultiPlus-II 3kW 120VAC 12VDC 600Ah Li Lynx Smart BMS & distributors Cerbo GX touch generator MPPT Orion Tr Smarts
- MultiPlus-II 3kW 230VAC 12VDC 400Ah Li Lynx Smart BMS Cerbo GX touch generator MPPT Orion-Tr Smarts
- MultiPlus-II 3kVA 230VAC 12VDC 600Ah Li Lynx Smart BMS & distributors Cerbo GX touch generator MPPT Extra Alternator & WS500
- MultiPlus-II 3KW 230VAC 12VDC 600Ah Li Lynx Smart BMS & distributors Cerbo GX touch generator MPPT Orion Tr Smarts
- US Van Manual & Drawing VEBus BMS V2 MultiPlus-II 3kVA 12V 120V 60Hz
- Manual and Drawing MultiPlus-II 15kVA 3Phase MPPT 250-100 Lynx Power In Distributors Cerbo GX Touch GX LTE 4G BYD Flex Lite
- MultiPlus-II 3Phase external transfer switch application 6xMP-II 15kVA and 160kVA generator
Technical informations
- Overview
- Sizing
- Did you Know?
-
The MultiPlus II is an inverter, battery charger, and transfer switch all in one compact package. Compatible with all battery types, this versatile inverter/charger is ready for use in recreational and professional vehicles, marine, off-grid, and on-grid solar and battery backup power applications.
Like the MultiPlus (square and thick), the MultiPlus II (rectangular and skinny) is a powerful inverter/charger with two AC outputs.
Key features:
- Slim profile, lower standby power
- Compatible with MPPT solar charger controllers and grid-tie PV inverters.
- Built-in anti-islanding functionality
- Easy installation and set up using VE.Configure software on a computer or laptop with an MK3-USB interface.
- Several monitoring and control options are available, such as Cerbo GX, laptop, computer, Bluetooth (with the optional VE.Bus Smart dongle), Battery Monitor, and Digital Multi Control Panel.
- Connect your system to the internet using a Cerbo GX or other Victron GX to remotely access, update settings, and monitor your system's performance data on VRM, Victron's free remote management portal.
-
The MultiPlus-II inverter/charger models range from 3000VA to the 15KVA unit, making it possible to use the MultiPlus-II for a small single-phase system, all the way up to 30kVa combined systems. In a 3-phase configuration, up to 3 sets of 6 MultiPlus II Inverter/Chargers can be combined for an impressive 90kVa of power and 1200 Amps of charging capacity.
The Victron naming convention explains the system's potential based on its design.
Example: MultiPlus-II 12/3000/120-50 2x120V
- 12 Volt DC battery
- 3000 Volt Amps continuous power rating
- 120 Amp DC battery charger
- 50 Amp AC pass-through transfer relay
- 120 Volt AC inverter
Related Reading >>> Victron Energy Inverter/Charger Buyer Checklist
-
The Multiplus II is a bi-directional inverter charger. If your inverter charger is in a camper van or RV, this means that even when connected to shore power, you have access to the full potential of the inverter. You’ll be able to charge your battery at maximum current without compromising your ability to power your van or RV off of a grid tie or generator. This could allow your system to run off of a smaller battery bank or a smaller, more fuel-efficient generator. This automatic function, called PowerAssist, is built into every Victron Energy inverter/charger. For more, read Victron’s PowerAssist Function Explained.